The stim test uses a known lie to calibrate the instrument and build confidence early in a lie detector test; here is how it works and how LieDetectorTest.com connects you with an experienced examiner.
Before your polygraph examiner asks the questions that actually matter, they conduct a brief but critical procedure called the stimulation test. This calibration step — using the card test, number test, or another known-lie format — is one of the most important parts of any polygraph exam. Here is everything you need to know about how stim tests work and why they matter.
TL;DR — The Short Version
- The stimulation test (stim test) is a brief calibration procedure where the examinee lies about a known fact — such as a number or card they selected — so the examiner can verify the polygraph is recording deceptive responses correctly.
- Its primary purpose is to orient the examinee to the testing process and strengthen the differential response pattern between truthful and deceptive answers on the scored questions.
- Common variants include the card test (select a card, deny all), the number test (pick a number between 3 and 7, deny all), and the known-solution biographical test.
- The stim test is not scored as pass or fail — it is a diagnostic and calibration tool conducted before the formal scored charts begin.
- Research by Widacki (2009) found that in 63% of deceptive subjects, reactions to critical questions were greater after a stimulation test, supporting its value in enhancing test accuracy.
- The APA Standards of Practice require acquaintance tests for all diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations.
Who This Guide Is For
- Anyone scheduled for a polygraph exam who wants to understand every step of the process
- Pre-employment candidates preparing for federal agency or law enforcement testing
- Criminal justice and psychology students studying polygraph methodology
- Attorneys advising clients who will undergo polygraph testing
- Polygraph examiner trainees learning about pretest calibration procedures
- Researchers and academics studying psychophysiological detection of deception
What Is a Stim Test in Polygraph?
Definition and Core Concept
A stim test — short for stimulation test, and sometimes called a known-lie test, demonstration test, acquaintance test, or sensitivity test — is a brief procedure conducted during the pretest phase of a polygraph examination [1]Verified The Polygraph and Lie Detection
Confirms stim test procedure involves picking a card or number between 3-7 and that the main purpose is to strengthen examinee belief in polygraph accuracy. It involves having the examinee deliberately lie about a known fact so that the examiner can observe and verify the physiological changes associated with that deception.
The concept is straightforward: the examiner asks you to select something — typically a number, a card, or a word — and then instructs you to deny your selection while connected to the polygraph instrument. Because the examiner knows which item you chose (or can determine it after the test), your lie becomes a controlled data point. The physiological response that appears when you deny your actual selection is compared against your responses when you truthfully deny the other items.
According to the National Research Council's landmark 2003 report, examinees in stimulation tests are presented with a set of similar items and directed to lie about one — for example, being asked to pick a card or a number between three and seven [1]Verified The Polygraph and Lie Detection
Confirms stim test procedure involves picking a card or number between 3-7 and that the main purpose is to strengthen examinee belief in polygraph accuracy. The main purpose of this procedure is to induce or strengthen in examinees the expectation that the polygraph can accurately determine the truthfulness of their answers [1]Verified The Polygraph and Lie Detection
Confirms stim test procedure involves picking a card or number between 3-7 and that the main purpose is to strengthen examinee belief in polygraph accuracy. This definition highlights that the stim test is not itself a scored examination — it is a preparatory and calibration tool. For a deeper look at how different polygraph techniques work, see our guide to the Utah Zone Comparison Test (UZCT).
Historical Background
The stimulation test has been part of polygraph practice since the earliest days of the discipline. Leonarde Keeler, widely regarded as the father of the modern polygraph [2]Verified Leonarde Keeler
Confirms Keeler used a card test during polygraph demonstrations and moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University, used a form of the card test in his demonstrations. During his college years at UC Berkeley, Keeler would conduct lie detector tests on fellow classmates using early prototypes, asking test subjects to pick a playing card from a deck before hooking them up to the instrument [2]Verified Leonarde Keeler
Confirms Keeler used a card test during polygraph demonstrations and moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University. A 1937 Newsweek article featured a photo recreation showing Keeler with playing cards and the polygraph [2]Verified Leonarde Keeler
Confirms Keeler used a card test during polygraph demonstrations and moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University.
Keeler moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University and ultimately became head of the laboratory in 1936 [16]Verified Leonarde Keeler Wikipedia Entry
Confirms Keeler moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University and became head in 1936. He opened the first polygraph school, known as the Keeler Institute, and became the first full-time private polygraph consultant [16]Verified Leonarde Keeler Wikipedia Entry
Confirms Keeler moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University and became head in 1936. His card test demonstration became a foundational element of polygraph methodology that survives in refined form today. For more on Keeler's remarkable contributions, explore the history of polygraph in the 1940s.
The technique was further formalized in 1963 when Cleve Backster published his Standardized Polygraph Notepack and Technique Guide for the Backster Zone Comparison Technique [4]Verified Standardized Polygraph Notepack and Technique Guide: Backster Zone Comparison Technique
Confirms Backster's 1963 publication codifying the Zone Comparison Technique, which formalized stim test procedures and psychological set theory. Backster's work codified the stim test procedures and introduced the concept of psychological set — the idea that examinees attend more to the category of question that presents the greater threat to their interests [5]Verified Psychological Set or Differential Salience: A Proposal for Reconciling Theory and Terminology
Proposes differential salience as a replacement for psychological set, with a stronger scientific foundation for explaining CQT functioning. The Zone Comparison Technique developed by Backster divided the examination into three zones: relevant questions (red zone), probable-lie comparison questions (green zone), and other questions (black zone) [1]Verified The Polygraph and Lie Detection
Confirms stim test procedure involves picking a card or number between 3-7 and that the main purpose is to strengthen examinee belief in polygraph accuracy. To understand how Backster's innovations shaped modern polygraph practice, read about the Richard Arther vs. Cleve Backster technique war.
What If the Stim Test Shows No Response?
Occasionally, the stim test reveals that an examinee shows minimal or no physiological differentiation between their known lie and their truthful denials. This does not necessarily mean anything negative about the examinee — it may indicate a sensor placement issue, an environmental factor, or that the examinee has an unusually flat physiological baseline.
When this occurs, the examiner will typically adjust the sensors, verify equipment settings, and may re-administer the stim test. If the issue persists, the examiner may explore alternative acquaintance test formats or evaluate whether the examinee is a suitable candidate for testing on that day. Medical conditions, certain medications, and extreme fatigue can all affect physiological responsiveness. The APA Standards of Practice emphasize that examiners should make reasonable efforts to determine that the examinee is a suitable candidate for polygraph testing [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. For more on how substances can influence your test, see our guide on whether Xanax can affect a lie detector test.
Your performance on the stim test does not directly affect your examination outcome. It is a calibration and preparation tool conducted before the formal scored charts begin.
Why Examiners Use the Stim Test
Calibrating the Instrument and the Examinee
The stimulation test serves multiple critical functions simultaneously. The U.S. Congress Office of Technology Assessment (OTA) confirmed in its 1983 report that stimulation tests are designed to improve test validity and are used in almost all field polygraph examinations [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations. The examiner administers a stimulation test designed to improve test validity by increasing differential responsivity between deceptive and nondeceptive subjects [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations.
The acquaintance test serves several key purposes as recognized by the American Polygraph Association: to familiarize the examinee with the test procedures, to properly set the gains and centerings of the instrument, to help detect countermeasures, and to assess the range of responsiveness of the examinee [15]Verified PDD Terminology Reference for the Science of Psychophysiological Detection of Deception
Provides standardized definitions including acquaintance test purposes: familiarizing examinee, setting gains, detecting countermeasures, and assessing responsiveness. Each of these functions contributes directly to the quality and reliability of the subsequent scored examination. For an understanding of how polygraph sensor technology works, visit our dedicated guide.
Strengthening Differential Salience
A key scientific function of the stim test is strengthening what researchers call differential salience — the principle that examinees respond more intensely to questions that are psychologically significant to them. Senter, Weatherman, Krapohl, and Horvath (2010) proposed that the concept of differential salience provides a more scientifically grounded framework than the older term psychological set for understanding why truthful and deceptive examinees respond differently to different question types [5]Verified Psychological Set or Differential Salience: A Proposal for Reconciling Theory and Terminology
Proposes differential salience as a replacement for psychological set, with a stronger scientific foundation for explaining CQT functioning.
According to Backster's original hypothesis, examinees are expected to attend more to the category of question that presents the greater threat to their interests, either the relevant or comparison questions [5]Verified Psychological Set or Differential Salience: A Proposal for Reconciling Theory and Terminology
Proposes differential salience as a replacement for psychological set, with a stronger scientific foundation for explaining CQT functioning. The stimulation test helps activate this differential response pattern before the scored charts begin. By demonstrating to the examinee that the instrument detects deception, the stim test increases the psychological significance of telling the truth — making the scored test questions more diagnostically powerful.
Reassuring Truthful Examinees and Increasing Detection Apprehension
The OTA report explained that stimulation tests are intended to reassure truthful subjects and provoke anxiety in deceptive subjects [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations. Their effect should be to increase differential responsivity of deceptive and nondeceptive subjects to different questions on the examination [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations. The U.S. Department of Justice Criminal Resource Manual similarly confirms that the stimulation procedure promotes the subject's belief in the machine and augments physical reactions by increasing fear and anxiety over detection [7]Verified Criminal Resource Manual 260: Polygraphs — Technique
Confirms that the stimulation procedure promotes the subject's belief in the machine and augments physical reactions by increasing detection apprehension.
This dual function makes the stim test a remarkably efficient tool. For truthful examinees, seeing the polygraph correctly identify their known lie provides confidence that the instrument works — reducing general anxiety that might otherwise contaminate their responses to scored questions. For deceptive examinees, the same demonstration heightens concern about being detected, which amplifies the physiological differences the examiner is looking for during the scored portion of the examination.
The Card Test Variant
How the Card Test Works
The card test is the oldest and most historically significant variant of the stimulation test, dating back to Leonarde Keeler's demonstrations in the 1920s and 1930s. During his college years, Keeler would ask test subjects to pick a playing card from a deck and then hook up the student to the polygraph device [2]Verified Leonarde Keeler
Confirms Keeler used a card test during polygraph demonstrations and moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University. According to the National Research Council, the examinee may be asked to pick one of several playing cards, and then to deny having picked each of the cards while connected to the polygraph machine [1]Verified The Polygraph and Lie Detection
Confirms stim test procedure involves picking a card or number between 3-7 and that the main purpose is to strengthen examinee belief in polygraph accuracy.
The examiner presents a spread of cards — typically five to seven — and asks the examinee to select one, note it, and return it to the deck. The examinee is then asked a series of questions such as, "Did you pick the king of hearts?" to which the examinee responds "No" each time, regardless of their actual selection [1]Verified The Polygraph and Lie Detection
Confirms stim test procedure involves picking a card or number between 3-7 and that the main purpose is to strengthen examinee belief in polygraph accuracy. Sometimes the cards are secretly marked or otherwise arranged so that the examiner is sure to know the correct answer [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations. However, many polygraph examiners consider this unnecessary because the technique is accurate enough without such measures [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations.
Advantages and Limitations
The card test is tangible, visual, and easy for examinees to understand. The physical act of selecting a card creates a clear, memorable event that anchors the known lie. This physicality can be especially effective for examinees who are anxious or unfamiliar with polygraph procedures.
However, the card test requires physical props and introduces variables related to card handling — such as the examinee accidentally revealing their selection or the cards being dealt inconsistently. For these practical reasons, many modern examiners have moved to the number test, which achieves the same calibration goals with fewer logistical requirements.
The Number Test Variant
How the Number Test Works
The number test is the most widely used modern variant of the stimulation test. According to the National Research Council, the examinee may be asked to pick a number between three and seven, and then to deny having picked each of the numbers while connected to the polygraph machine [1]Verified The Polygraph and Lie Detection
Confirms stim test procedure involves picking a card or number between 3-7 and that the main purpose is to strengthen examinee belief in polygraph accuracy. The examiner asks the examinee to write down a number within this restricted range, then poses a series of questions: "Is the number you wrote down the number three?" "Is the number you wrote down the number four?" — and so on through seven.
The restricted range of numbers (3 to 7) is deliberately chosen to avoid primacy and recency effects — psychological phenomena where people show heightened responses to items at the beginning or end of a series. By excluding the numbers 1, 2, 8, 9, and 10, the number test ensures that all options occupy middle positions, producing cleaner physiological data for calibration purposes.
Why the Number Test Has Become Standard
The number test has largely replaced the card test in modern practice because it is faster to administer, eliminates variables related to card handling, and requires no physical props. The Federal Psychophysiological Detection of Deception Examiner Handbook, dated 2 October 2006, prescribes uniform PDD procedures for DoD elements and federal agencies [20]Verified Meta-Analytic Survey of Criterion Accuracy of Validated Polygraph Techniques
Confirms 89% accuracy for diagnostic testing (CI 83%-95%), 85% for multi-issue testing (CI 77%-93%), and 87% overall (CI 80%-94%), and the number test format is the standard acquaintance test variant used in federal polygraph examinations. The Federal Government's version of the acquaintance test is covered in Chapter 7 of the handbook [20]Verified Meta-Analytic Survey of Criterion Accuracy of Validated Polygraph Techniques
Confirms 89% accuracy for diagnostic testing (CI 83%-95%), 85% for multi-issue testing (CI 77%-93%), and 87% overall (CI 80%-94%).
Widacki (2009) specifically studied the timing of the stimulation number test in his research published in European Polygraph, finding that in 63% of deceptive subjects, reactions to critical questions were greater in the control question test administered after the stimulation test compared to before [6]Verified When Should the Polygraph Stimulation Number Test Be Performed?
Found that in 63% of deceptive subjects, reactions to critical questions were greater after the stimulation test than before. This finding provides direct evidence that the number test effectively enhances the diagnostic power of the subsequent scored examination.
Other Known-Lie Variants
Known-Solution Biographical Test
Some examiners use a known-solution biographical test as an alternative to the card or number test. In this variant, the examiner asks questions about known biographical facts — such as the examinee's first name, birth month, or city of residence — and instructs the examinee to deny one of these known facts. Because the examiner already knows the correct answers, the examinee's denial of their true biographical detail serves as the controlled lie.
This variant has the advantage of feeling more natural and less game-like than picking a card or number. It also allows the examiner to assess physiological responsiveness using stimuli that are personally meaningful to the examinee, which can produce stronger and more diagnostically useful responses.
Directed-Lie Acquaintance Tests
In some protocols, the acquaintance test incorporates directed lies — questions where the examinee is explicitly instructed to lie. For example, the examiner might say, "When I ask whether you have ever told a lie to avoid getting in trouble, I want you to answer 'No.'" This format has the benefit of ensuring the examinee lies about something personally relevant, potentially generating a stronger physiological response.
The choice of acquaintance test variant depends on the testing protocol being used, the examiner's training, and agency requirements. The APA Standards of Practice mandate an acquaintance test for specific examination types but allow professional discretion in selecting the appropriate format [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. For information on how new examiners learn these procedures, see our guide on polygraph examiner supervision requirements.
Stim Test vs. Acquaintance Test
Understanding the Terminology
The terms stimulation test and acquaintance test are often used interchangeably in polygraph practice, though they emphasize slightly different aspects of the same procedure. Stimulation test emphasizes the psychological conditioning function — the way the procedure stimulates and strengthens the examinee's differential response pattern. Acquaintance test emphasizes the familiarization function — how the procedure acquaints the examinee with the testing process.
Other synonyms encountered in professional literature include numbers test, demonstration test, practice test, sensitivity test, and calibration verification of sensitivity test (CVOS) [15]Verified PDD Terminology Reference for the Science of Psychophysiological Detection of Deception
Provides standardized definitions including acquaintance test purposes: familiarizing examinee, setting gains, detecting countermeasures, and assessing responsiveness. The APA's PDD Terminology Reference provides standardized definitions for these terms, confirming that the acquaintance test purposes include familiarizing the examinee, setting gains, detecting countermeasures, and assessing responsiveness [15]Verified PDD Terminology Reference for the Science of Psychophysiological Detection of Deception
Provides standardized definitions including acquaintance test purposes: familiarizing examinee, setting gains, detecting countermeasures, and assessing responsiveness. All of these terms refer to the same core procedure.
Why the Distinction Matters
Understanding the dual nature of the stim/acquaintance test helps explain why it is so effective. The familiarization function reduces test anxiety for all examinees, which improves overall data quality. The stimulation function selectively enhances the physiological differentiation between truthful and deceptive responses, which improves diagnostic accuracy.
Research by Saldžiūnas and Kovalenko (2009) proposed a probability framework for understanding the relationship between stimulus psychological significance and physiological response magnitude [9]Verified Probability Assessment of the Value of Psychophysiological Stimuli
Proposes a probability framework for understanding the relationship between stimulus psychological significance and physiological response magnitude. Their work helps explain why the stim test is effective: by establishing the polygraph's ability to detect a known lie, the procedure increases the psychological significance of all subsequent test questions — making truthful and deceptive responses more distinguishable from one another.
When the Stim Test Is Administered
Timing Within the Examination
The stim test is typically administered after the pretest interview and before the first scored chart. However, some protocols call for administering a stim test between the first and second scored charts, or even at multiple points during the examination [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations. The OTA report noted that although not actually a part of the pretest, stimulation tests can be given either before the first actual set of test questions or after the first chart has been recorded [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations.
Matte (2012) specifically examined how stimulation test timing influences examinee psychological set and physiological response patterns across multiple chart positions [12]Verified Effect of the Stimulation Test Administered Before and After the First Relevant Chart of the Control Question Test
Examines how stimulation test timing influences examinee psychological set and physiological response patterns across multiple chart positions. His research explored whether administering the stim test before versus after the first relevant chart of the control question test affected the quality of subsequent physiological data, finding that timing can influence the examinee's psychological orientation to the scored questions.
APA Requirements
The APA Standards of Practice (amended August 23, 2024) are clear: examiners shall conduct an acquaintance test for all diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. This covers the vast majority of professional polygraph examinations. The standards also mandate that examinations shall be scheduled for not less than 90 minutes [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling, and that a member polygraph examiner shall not conduct more than five examinations of any type in one day [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling.
The APA further requires that member polygraph examiners use evidence-based validated testing techniques [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. All validated polygraph techniques include a stim test component, making it an integral part of professionally administered examinations. If you're preparing for an upcoming examination, you can book a polygraph test with confidence that proper calibration procedures will be followed.
The Science Behind Stim Tests
Research Evidence for Stim Test Effectiveness
Multiple peer-reviewed studies support the effectiveness of the stimulation test in improving polygraph accuracy. Widacki (2009) found that in 63% of deceptive subjects, reactions to critical questions were greater after the stimulation test than before [6]Verified When Should the Polygraph Stimulation Number Test Be Performed?
Found that in 63% of deceptive subjects, reactions to critical questions were greater after the stimulation test than before. This finding directly demonstrates that the stim test enhances the physiological differentiation that examiners rely on to make accurate decisions.
The OTA report confirmed that some research suggests stimulation tests increase the validity of polygraph examinations [8]Verified Scientific Validity of Polygraph Testing: A Research Review and Evaluation
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations. The APA's 2011 meta-analytic survey of validated polygraph techniques — all of which include a stim test — found that single-issue diagnostic testing produced an aggregated decision accuracy of 89% (confidence interval 83%–95%), with an estimated inconclusive rate of 11% [21]Verified A Comprehensive Meta-Analysis of the Comparison Question Polygraph Test
Meta-analysis of 138 datasets confirmed CQT accuracy estimates generally over 85% and found motivation positively correlated with accuracy. Multi-issue testing produced 85% accuracy (CI 77%–93%), and the combination of all validated techniques produced 87% accuracy (CI 80%–94%) [21]Verified A Comprehensive Meta-Analysis of the Comparison Question Polygraph Test
Meta-analysis of 138 datasets confirmed CQT accuracy estimates generally over 85% and found motivation positively correlated with accuracy.
More recently, Honts, Thurber, and Handler (2021) conducted a comprehensive meta-analysis of 138 datasets examining the Comparison Question Test and confirmed CQT accuracy estimates generally over 85%, with motivation positively correlated with accuracy [22]Verified Increasing Irrelevant Stimuli Increases Ability to Detect Countermeasures
Found that increasing irrelevant stimuli in P300-based CIT improved countermeasure detection, advancing complex trial protocol methodology. Their research found no publication bias and concluded that CQT testing can be highly accurate, particularly in real-world forensic settings where stakes are high.
Stimulus Set Size and Detection Efficiency
The science behind why stim tests work extends into fundamental psychophysiology research. Lieblich (1970) demonstrated that detection scores did not decline as stimulus set size increased, and Signal Detection analysis suggested enhanced autonomic discrimination with larger sets [10]Verified Efficiency of GSR Detection of Information as a Function of Stimulus Set Size
Demonstrated that detection scores did not decline as stimulus set size increased, and Signal Detection analysis suggested enhanced autonomic discrimination with larger sets. This finding, which became foundational to what is known as the Dichotomization Theory, helps explain why the relatively small stimulus set used in the number test (five items: 3 through 7) is diagnostically effective.
Lieblich (1982) further identified a significant interaction between stimulus significance and relative frequency, finding that the skin conductance response advantage for low-probability stimuli was substantially greater when those stimuli also held personal relevance [11]Verified Interactive Effects of Stimulus Probability and Significance on the Skin Conductance Response
Identified a significant interaction between stimulus significance and relative frequency, with greater skin conductance response advantage for low-probability stimuli of personal relevance. This research supports the principle that the stim test works by making the examinee's known lie a personally relevant, psychologically significant stimulus — exactly the conditions that produce the strongest physiological differentiation.
Monte Carlo Validation and Modern Research
Raskin, Honts, Nelson, and Handler (2015) used Monte Carlo simulation methods to estimate polygraph validity across different conditions, showing unweighted accuracy of 0.92 to 0.94 for three test charts with grand total scores [19]Verified Federal Psychophysiological Detection of Deception Examiner Handbook
Confirms the handbook dated 2 October 2006 prescribes uniform PDD procedures for DoD elements and federal agencies, with Chapter 7 covering the acquaintance test. This statistical modeling confirmed high accuracy estimates consistent with empirical findings, providing additional confidence that the validated techniques — which all incorporate stimulation tests — produce reliable results.
Barland (1985) proposed an innovative method for estimating individual test accuracy from physiological response magnitudes, laying important groundwork for confidence-based polygraph decision reporting. This approach relates directly to stim test calibration, as the magnitude of response during the known-lie provides a baseline for evaluating the strength of responses during scored questions. Learn more about Barland's contributions in our profile of Gordon Barland: the researcher who shaped polygraph science.
Hu, Hegman, Landry, and Rosenfeld (2012) found that increasing the number of irrelevant stimuli in P300-based concealed information tests improved the ability to detect countermeasure use [23]Verified DoD, DIU Announce Polygraph+ Credibility Assessment Modernization Effort
Confirms the Polygraph+ initiative with Carnegie Mellon, MIT, University of Maryland, and Columbia University partnerships. While this research focused on brain-wave testing rather than traditional polygraph, it advances the broader scientific understanding of how stimulus structure affects deception detection — principles that apply directly to the design of effective stimulation tests.
What You Experience as the Examinee
The Selection Phase
During the stim test, the examiner will first instruct you to select a number (typically between 3 and 7) and write it down, or to pick a card from a small set. The examiner may or may not know your selection at this point — some protocols use openly known selections while others use secretly marked cards or envelopes that allow the examiner to determine the answer after the test.
You will already be connected to the polygraph instrument at this point, with sensors measuring your respiration, cardiovascular activity, and electrodermal response. The examiner will ensure you are comfortable and that all sensors are properly positioned before beginning the questioning sequence.
The Questioning Sequence
The examiner will then ask you a series of questions — one for each item in the set. For a number test with the range 3 to 7, you will hear five questions: "Regarding the number you wrote down — was it the number three?" through "Was it the number seven?" You will answer "No" to each question, including the one that is your actual selection.
This is the only time during the examination that you are explicitly instructed to lie. The examiner will typically wait 15 to 25 seconds between questions to allow your physiological responses to return to baseline before asking the next question. This inter-stimulus interval is critical for obtaining clean, interpretable data.
After the Stim Test
After completing the stim test, the examiner will briefly review the physiological tracings. In many protocols, the examiner will then share the results with you — showing that the instrument correctly identified which number you selected. This demonstration reinforces your confidence in the polygraph's accuracy.
The entire stim test typically takes 3 to 5 minutes, representing a small fraction of the overall examination time. The APA requires examinations to be scheduled for not less than 90 minutes [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. Following the stim test, the examiner will proceed to the scored portion of the examination using the validated technique appropriate for the type of examination being conducted. Understanding how the process works can help alleviate anxiety — for more preparation tips, learn about what happens if you lie on a polygraph.
Professional Standards and Requirements
APA Standards of Practice
The American Polygraph Association Standards of Practice (amended August 23, 2024) establish clear requirements for the acquaintance test. Section 1.7.6 states that examiners shall conduct an acquaintance test for all diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. This mandate ensures that every professionally administered polygraph examination includes this essential calibration step.
The standards also require that member polygraph examiners use evidence-based validated testing techniques [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling, supported by research conducted in accordance with APA research standards. Where examiners deviate from the protocols of a validated polygraph technique, the deviations should be explained in writing [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. An audio or audio-video recording of all phases of the exam must be maintained for a minimum of one year [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. These rigorous standards ensure consistent, high-quality examinations across the profession.
Federal Government Standards
The Federal Psychophysiological Detection of Deception Examiner Handbook, dated 2 October 2006, prescribes uniform PDD procedures for DoD elements and federal agencies [20]Verified Meta-Analytic Survey of Criterion Accuracy of Validated Polygraph Techniques
Confirms 89% accuracy for diagnostic testing (CI 83%-95%), 85% for multi-issue testing (CI 77%-93%), and 87% overall (CI 80%-94%). The handbook's Chapter 7 specifically addresses the federal government's version of the acquaintance test, which serves to demonstrate and acquaint the examinee with the basic concepts of the PDD examination [20]Verified Meta-Analytic Survey of Criterion Accuracy of Validated Polygraph Techniques
Confirms 89% accuracy for diagnostic testing (CI 83%-95%), 85% for multi-issue testing (CI 77%-93%), and 87% overall (CI 80%-94%). The provisions apply to all DoD elements that use PDD and, by agreement, to other federal law enforcement, counterintelligence, and security agencies [20]Verified Meta-Analytic Survey of Criterion Accuracy of Validated Polygraph Techniques
Confirms 89% accuracy for diagnostic testing (CI 83%-95%), 85% for multi-issue testing (CI 77%-93%), and 87% overall (CI 80%-94%).
For those interested in how polygraph testing serves broader national interests, our guide on lie detectors and national security provides further context. The Department of Defense also continues to invest in polygraph modernization through initiatives partnering with leading research institutions [24]Verified A Method of Estimating the Accuracy of Individual Control Question Polygraph Tests
Proposed an innovative method for estimating individual test accuracy from physiological response magnitudes, laying groundwork for confidence-based reporting.
Countermeasure Detection
One of the stated purposes of the acquaintance test is to help detect countermeasures [15]Verified PDD Terminology Reference for the Science of Psychophysiological Detection of Deception
Provides standardized definitions including acquaintance test purposes: familiarizing examinee, setting gains, detecting countermeasures, and assessing responsiveness. Countermeasures are any actions an examinee takes to manipulate their physiological responses during the examination. If an examinee is attempting to use physical or mental countermeasures during the stim test, the examiner may notice unusual patterns — such as artificially suppressed or augmented responses — that warrant further investigation before proceeding to the scored examination.
Because the examiner knows the correct answer during the stim test, they can compare the expected response pattern against what actually appears in the physiological tracings. Deviations from the expected pattern may indicate countermeasure attempts, medical issues, or other factors that the examiner needs to address. For more on how polygraph testing handles deception attempts, explore whether hypnosis can beat a polygraph.
Gołaszewski (2022) demonstrated the importance of objective calibration procedures in evidentiary polygraph chart interpretation, discussing how confirmation bias can affect outcomes and reinforcing why standardized procedures like the stim test are critical to maintaining examination integrity [13]Verified Should Blind Evaluation of Polygraph Charts Be a Mandatory Procedure in Evidentiary Examinations?
Demonstrates the importance of objective calibration procedures and discusses confirmation bias in evidentiary polygraph chart interpretation.
The Role of the Stim Test in Polygraph Accuracy
Contribution to Validated Technique Accuracy
Every validated polygraph technique includes a stimulation test as a standard component. Nelson (2015) confirmed that event-specific diagnostic polygraphs provide mean accuracy of 0.89, and that the purpose of the acquaintance test includes orienting the examinee to testing procedures [18]Verified Monte Carlo Estimates of the Validity of Polygraph Testing
Used Monte Carlo simulation methods to estimate polygraph validity, showing unweighted accuracy of.92 to.94 for three test charts with grand total scores. The stim test is not an optional add-on — it is an integral part of the validated testing protocols that produce these high accuracy rates.
The APA's meta-analytic survey encompassed 38 studies involving 32 different samples with 295 scorers who provided 11,737 scored results from 3,723 examinations [21]Verified A Comprehensive Meta-Analysis of the Comparison Question Polygraph Test
Meta-analysis of 138 datasets confirmed CQT accuracy estimates generally over 85% and found motivation positively correlated with accuracy. These results included 6,109 scores of 2,015 confirmed deceptive examinations and 5,628 scores of 1,708 confirmed truthful examinations [21]Verified A Comprehensive Meta-Analysis of the Comparison Question Polygraph Test
Meta-analysis of 138 datasets confirmed CQT accuracy estimates generally over 85% and found motivation positively correlated with accuracy. All of these validated techniques incorporated a stimulation test, making it a foundational element of the evidence base for polygraph accuracy.
Implications for Examinees
For examinees, the stim test should be viewed as a positive and reassuring part of the polygraph process. It demonstrates that the instrument is working properly and that your physiological responses are being accurately recorded. If you are truthful, the stim test actually works in your favour by calibrating the examination to your individual physiology and ensuring the examiner can distinguish between your truthful and deceptive response patterns.
The stim test also provides an opportunity to become comfortable with the testing process before the scored questions begin. Many examinees report that the stim test reduces their anxiety about the examination, which can improve the quality of the scored data. If you want to learn more about how spontaneous physiological variations are managed during testing, see our guide on spontaneous fluctuation rate in polygraph testing.
To explore the full range of polygraph research supporting these procedures, visit our Polygraph Research Database, which contains hundreds of peer-reviewed studies on psychophysiological detection of deception.
Frequently Asked Questions
What happens if the examiner cannot detect my known lie during the stim test?
If the stim test shows minimal physiological differentiation, the examiner will typically adjust sensor placement, verify equipment settings, and may re-administer the test. This outcome does not mean you are doing anything wrong — it may indicate a technical issue that needs to be resolved before proceeding. The APA Standards emphasize making reasonable efforts to ensure the examinee is suitable for testing [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling.
Can I refuse to take the stim test?
The stim test is a standard part of professionally administered polygraph examinations and is required by APA Standards of Practice for most examination types [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. Refusing the stim test would likely prevent the examination from proceeding, as it is an essential calibration step that ensures accurate results.
Why do examiners use the number test instead of the card test?
The number test is a streamlined modern adaptation that achieves the same calibration and psychological conditioning goals without requiring physical cards. It is faster to administer and eliminates variables related to card handling. The restricted number range (typically 3 to 7) also avoids primacy and recency effects that could contaminate the physiological data.
Does the stim test actually improve polygraph accuracy?
Yes, research supports that the stim test enhances examination accuracy. Widacki (2009) found that in 63% of deceptive subjects, reactions to critical questions were greater after the stimulation test than before [6]Verified When Should the Polygraph Stimulation Number Test Be Performed?
Found that in 63% of deceptive subjects, reactions to critical questions were greater after the stimulation test than before. The APA's 2011 meta-analysis confirmed that validated polygraph techniques — all of which include a stim test — produce decision accuracy rates of up to 89% for diagnostic testing [21]Verified A Comprehensive Meta-Analysis of the Comparison Question Polygraph Test
Meta-analysis of 138 datasets confirmed CQT accuracy estimates generally over 85% and found motivation positively correlated with accuracy.
How long does the stim test take?
A typical stim test takes 3 to 5 minutes, including the selection phase, the questioning sequence, and the examiner's brief review of the tracings. This is a small fraction of the overall examination time, which the APA requires to be scheduled for not less than 90 minutes [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling.
Is the stim test required for every type of polygraph examination?
The APA Standards of Practice require an acquaintance test for all diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations [3]Verified APA Standards of Practice
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling. This covers the vast majority of professional polygraph examinations. Some ongoing monitoring or follow-up tests may have different protocols.
What is the difference between a stim test and an acquaintance test?
These terms are often used interchangeably. 'Stimulation test' emphasizes the psychological conditioning function, while 'acquaintance test' emphasizes familiarization with the testing process. Other synonyms include numbers test, demonstration test, practice test, and calibration verification of sensitivity test (CVOS) [15]Verified PDD Terminology Reference for the Science of Psychophysiological Detection of Deception
Provides standardized definitions including acquaintance test purposes: familiarizing examinee, setting gains, detecting countermeasures, and assessing responsiveness. All refer to the same core procedure.
Can the stim test detect countermeasures?
Yes. One of the stated purposes of the acquaintance test is to help detect countermeasures [15]Verified PDD Terminology Reference for the Science of Psychophysiological Detection of Deception
Provides standardized definitions including acquaintance test purposes: familiarizing examinee, setting gains, detecting countermeasures, and assessing responsiveness. If an examinee is attempting to manipulate their physiological responses during the stim test, the examiner may notice unusual patterns that warrant further investigation before proceeding to the scored examination.
Does the stim test count toward my pass or fail result?
No. The stim test is not scored as part of the formal examination outcome. It is purely a calibration and preparation tool. Your examination result is determined solely by your physiological responses to the scored relevant and comparison questions administered during the formal charts that follow the stim test.
Sources & References
Confirms stim test procedure involves picking a card or number between 3-7 and that the main purpose is to strengthen examinee belief in polygraph accuracy
Confirms Keeler used a card test during polygraph demonstrations and moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University
Confirms APA requires acquaintance tests for diagnostic, evidentiary, paired-testing, initial screening, and initial investigative examinations, and mandates 90-minute minimum exam scheduling
Confirms Backster's 1963 publication codifying the Zone Comparison Technique, which formalized stim test procedures and psychological set theory
Proposes differential salience as a replacement for psychological set, with a stronger scientific foundation for explaining CQT functioning
Found that in 63% of deceptive subjects, reactions to critical questions were greater after the stimulation test than before
Confirms that the stimulation procedure promotes the subject's belief in the machine and augments physical reactions by increasing detection apprehension
Confirms that stim tests are designed to improve test validity and are used in almost all field polygraph examinations
Proposes a probability framework for understanding the relationship between stimulus psychological significance and physiological response magnitude
Demonstrated that detection scores did not decline as stimulus set size increased, and Signal Detection analysis suggested enhanced autonomic discrimination with larger sets
Identified a significant interaction between stimulus significance and relative frequency, with greater skin conductance response advantage for low-probability stimuli of personal relevance
Examines how stimulation test timing influences examinee psychological set and physiological response patterns across multiple chart positions
Demonstrates the importance of objective calibration procedures and discusses confirmation bias in evidentiary polygraph chart interpretation
Found differential juror reactions depending on the type of polygraph test presented, with implications for how polygraph evidence should be explained
Provides standardized definitions including acquaintance test purposes: familiarizing examinee, setting gains, detecting countermeasures, and assessing responsiveness
Confirms Keeler moved to Chicago in 1930 to work at the Scientific Crime Detection Laboratory at Northwestern University and became head in 1936
Confirms diagnostic polygraphs provide mean accuracy of.89 and that the purpose of the acquaintance test includes orienting the examinee to testing procedures
Used Monte Carlo simulation methods to estimate polygraph validity, showing unweighted accuracy of.92 to.94 for three test charts with grand total scores
Confirms the handbook dated 2 October 2006 prescribes uniform PDD procedures for DoD elements and federal agencies, with Chapter 7 covering the acquaintance test
Confirms 89% accuracy for diagnostic testing (CI 83%-95%), 85% for multi-issue testing (CI 77%-93%), and 87% overall (CI 80%-94%)
Meta-analysis of 138 datasets confirmed CQT accuracy estimates generally over 85% and found motivation positively correlated with accuracy
Found that increasing irrelevant stimuli in P300-based CIT improved countermeasure detection, advancing complex trial protocol methodology
Confirms the Polygraph+ initiative with Carnegie Mellon, MIT, University of Maryland, and Columbia University partnerships
Proposed an innovative method for estimating individual test accuracy from physiological response magnitudes, laying groundwork for confidence-based reporting
To experience how a stim test calibrates your exam, find a lie detector test near you and compare pricing at professional locations near you.