29 Examiners Available Now — Contact Them DirectlyNo Booking Fee — You Pay Your Examiner Directly270+ Testing Locations Across the U.S., Canada & UKFree Polygraph Research Database — 44,000+ StudiesWe Promote Clear Standards & Best Practice in Private Polygraph TestingLearning Center — Independent Guides to Every Type of Polygraph TestSame-Day Verbal Result · Written Report Within 48 HoursVetted Examiners Trained at Accredited Polygraph Schools100% Confidential — Private, Appointment-Only TestingPolygraph Glossary (600+ Terms), Book Library & School DirectoryTrusted by 10,000+ Clients, Attorneys & Organizations
LieDetectorTest.com Stop guessing. Get the truth.

Home › Polygraph Research › Journals › International Journal of Psychophysiology

Journal file

International Journal of Psychophysiology

69 peer-reviewed polygraph studies · 1991–2025

69Studies
122Authors
8Categories
1991–2025Year range

Authors in International Journal of Psychophysiology [122]

J. Peter Rosenfeld 9 Eitan Elaad 6 Elena Labkovsky 5 John J. Furedy 5 Matthias Gamer 3 Heinz Werner Gödert 3 Tokihiro Ogawa 2 A. Ward 2 Liza Zvi 2 Charles Robert Honts 2 Geert Crombez 2 Yuki Hamamoto 2 Michael R. Winograd 2 Xiaoqing Hu 2 J. Meixner 2 Wolfgang Ambach 2 Fren T. Y. Smulders 2 Gershon Ben-Shakhar 2 Matthew Soskins 2 A. Vincent 2 Jerzy Wojciechowski 1 Joseph M. Olson 1 Gayathri Subramanian 1 Zofia Kosowska 1 Kasjan Pietras 1 Reo Takahashi 1 Yusuke Shibuya 1 Michiko Tsuneoka 1 Nathalie klein Selle 1 A. C. Ward 1 E. J. Sitar 1 J. D. Wasserman 1 J. Huihui Zheng Peter Rosenfeld 1 Xiaohong Deng 1 Yang Lu 1 Chao Xue 1 Ying Wang 1 Erhu Zhang 1 Gejun Yan 1 Dan Ouyang 1 N. C. Klein Selle G. Gueta L. Ben-Shakhar Deouell 1 Y.G. K.V. Pavlov Zlokazov 1 E.J. J.H. Lee Lee 1 J. Joseph Olson Peter Rosenfeld 1 Taewoo Kim 1 Ella Perrault 1 J.P. J. Rosenfeld E. Olson A.C. Sitar Ward 1 J. Drapekin 1 S. Tullman 1 Gáspár Lukács 1 Béla Weiss 1 Vera Daniella Dalos 1 Tünde Kilencz 1 C. Antal 1 Á. Szabó 1 Artem Kovalev 1 Elizaveta Luniakova 1 Galina Menshikova 1 X. Deng 1 Anne Ward 1 Vincent Frigo 1 Jesse Drapekin 1 Aldert Vrij 1 Takuro Otsuka 1 Mitsuyoshi Mizutani 1 Fumio Yamada 1 Shinji Hira 1 Yuhki Yamashita 1 Yoko Saragai 1 Isato Furumitsu 1 Takehiro Komatsu 1 Mariko Takeuchi 1 Hitoshi Yonemori 1 Seigo Ishimura 1 Yuko Sugisawa 1 Michelle C. Phillips 1 J. Peth 1 J. Kim 1 Giorgio Ganis 1 G. E. Ben-Shakhar Meijer 1 L. Zvi 1 I. Nachson 1 M. A. Kireev S. Korotkov Medvedev 1 S. Y. Hira Saragai 1 I. Matsuda 1 T. Ogawa 1 A. Sokolovsky 1 J. Rothenberg 1 Maxim Kireev 1 Izumi Matsuda 1 Hiroshi Nittono 1 W. Ambach 1 S. Bursch 1 R. Stark 1 D. Vaitl 1 A. Osugi 1 K. Vandenbosch 1 Bruno J. Verschuere 1 DeClercq 1 J.P. M.R. Rosenfeld A. Winograd E.B. Haynes Labkovsky 1 B. J.P. Verschuere M. Rosenfeld E. Winograd J.R. Labkovsky Wiersema 1 Rudolf Stark 1 Martin Peper 1 Dieter Vaitl 1 J.R. Biroschak 1 Vahid Abootalebi 1 Mohammad Hassan Moradi 1 Mohammad Ali Khalilzadeh 1 Hans-Georg Rill 1 Gerhard Vossel 1 F. Fang 1 Y. Liu 1 Z. Shen 1 T. Niendam 1 K. Fukuda 1 J.Peter Rosenfeld 1 John J.B. Allen 1 John C. Kircher 1 David C. Raskin 1 M.M. Johnson 1 Leonard Saxe 1 R.T. Posner 1

Research topics

All studies [69]

Every peer-reviewed study from International Journal of Psychophysiology in our database, ordered newest first.

[002]
Reo Takahashi, Yusuke Shibuya, Michiko Tsuneoka, Tokihiro Ogawa (2024)

Area measure of skin conductance in the Concealed Information Test

SC area showed acceptable performance for CIT classification and exceeded chance-level discrimination even for low-responsive participants, though equivalence with traditional…

Concealed Information Test (CIT) CIT Laboratory Study Scoring Methods Japan
[003]
Nathalie klein Selle (2020)

Is the CIT susceptible to misleading information? A constructive replication

Misleading information reduced explicit memory of mock crime details, but physiological CIT responses (skin conductance and respiration) were only partially…

Concealed Information Test (CIT) CIT Laboratory Study Accuracy & Validity Theory & Mechanisms Countermeasures
[004]
A. C. Ward, J. Peter Rosenfeld, E. J. Sitar, J. D. Wasserman (2020)

The effect of retroactive memory interference on the P300-based Complex Trial Protocol (CTP)

Retroactive memory interference did not threaten P300-based CTP accuracy, with significant probe vs. irrelevant amplitude differences maintained across all experimental…

Neuroimaging & New Technologies EEG/P300 CIT Laboratory Study Countermeasures Accuracy & Validity
[006]
N. C. Klein Selle G. Gueta L. Ben-Shakhar Deouell (2018)

What mechanisms underlie ERP-based concealed information detection?

P3 responses and multivariate brain patterns showed equivalent strength whether participants concealed or revealed information, but were strongly influenced by…

Concealed Information Test (CIT) CIT EEG/P300 Laboratory Study Theory & Mechanisms Machine Learning
[008]
E.J. J.H. Lee Lee (2018)

Increase of Lie Detection Accuracy through Integrated Measurement of Pupil Dilation and Polygraph

The integrated measurement of pupil dilation and polygraph increased lie detection accuracy compared to single-modality approaches, though specific accuracy rates…

Neuroimaging & New Technologies Eye Tracking Laboratory Study Accuracy & Validity CQT
[009]
J. Joseph Olson Peter Rosenfeld, Taewoo Kim, Ella Perrault (2018)

The effect of countermeasures against the reaction time based concealed information test on the P300 index of knowledge recognition: A combined RT and P300-based test

Countermeasures successfully defeated the RT-based test by reversing the normal probe-irrelevant RT pattern, but paradoxically increased P300 probe-irrelevant differences, leading…

Countermeasures Research CIT Countermeasures Laboratory Study EEG/P300
[012]
Liza Zvi, Eitan Elaad (2016)

Contributions of personality dimensions to spontaneous and deliberate information processing in the guilty actions test

Introversion predicted enhanced skin conductance responses to critical items only during first presentations of early questions, while extraversion was linked…

Concealed Information Test (CIT) CIT Laboratory Study Theory & Mechanisms Accuracy & Validity
[013]
Gáspár Lukács, Béla Weiss, Vera Daniella Dalos, Tünde Kilencz, C. Antal, Á. Szabó (2016 • INDEPENDENT REPLICATION)

The First Independent Study on the Complex Trial Protocol Version of the P300-Based Concealed Information Test

First independent replication of Rosenfeld’s Complex Trial Protocol. Corroborated accuracy and countermeasure resistance of the CTP when using probe vs.…

Neuroimaging & New Technologies CIT EEG/P300 Laboratory Study Countermeasures Accuracy & Validity
[015]
X. Deng, J. Peter Rosenfeld, A. Ward, Elena Labkovsky (2016)

Superiority of visual (verbal) vs. auditory test presentation modality in a P300-based CIT: The complex-trial protocol for concealed autobiographical memory detection

Visual presentation produced significantly larger probe-irrelevant P300 differences (effect sizes 0.19-0.31) and higher detection accuracy than auditory presentation. The study…

Neuroimaging & New Technologies CIT Laboratory Study EEG/P300 Neuroimaging Accuracy & Validity
[017]
Charles Robert Honts (2015)

Psychophysiological detection of deception and Preliminary Process Theory: a comment on Palmatier and Rovner (2015)

The commentary acknowledges common psychophysiological processes underlie CQT and CIT but finds arguments for Preliminary Process Theory unconvincing, calling for…

Foundational & Historical Research Theory & Mechanisms Review Article CQT CIT
[018]
Geert Crombez (2015)

The cognitive mechanisms underlying deception: An event-related potential study

Lying produced significantly longer reaction times (d = 1.91), higher error rates (d = 1.24), an enhanced N200, and a…

Neuroimaging & New Technologies EEG/P300 CIT Laboratory Study Theory & Mechanisms Accuracy & Validity
[019]
Aldert Vrij (2015)

The protection of innocent suspects: a comment on Palmatier and Rovner (2015)

The commentary argues that CQT and CIT differ fundamentally in how they protect innocent suspects, with this difference representing a…

Foundational & Historical Research CQT CIT Theory & Mechanisms Review Article Ethics & Policy
[020]
Liza Zvi, Eitan Elaad (2014)

Personality dimensions predict psychophysiological responses in the Concealed Information Test

Introversion predicted enhanced skin conductance responses to critical items only during the first repetition of early questions, explained by orienting…

Concealed Information Test (CIT) CIT Laboratory Study Accuracy & Validity Theory & Mechanisms
[021]
Takuro Otsuka, Mitsuyoshi Mizutani, Fumio Yamada (2014)

The processes involved with fewer eyeblinks in a concealed information test

Fewer eyeblinks and longer first-blink latency occurred for crime-related items in both concealing and non-concealing groups, while heart rate differences…

Concealed Information Test (CIT) CIT Laboratory Study Eye Tracking Accuracy & Validity Theory & Mechanisms
[022]
Shinji Hira, Yuhki Yamashita, Yoko Saragai, Yuki Hamamoto, Isato Furumitsu (2014)

Effects of countermeasures on P300-based concealed information test using a new multiple probe protocol

The study examined countermeasure resistance of a new multiple probe protocol for P300-based CIT, though specific detection rates and statistical…

Countermeasures Research CIT EEG/P300 Countermeasures Laboratory Study Japan
[023]
(2014)

Functional neuroimaging of deception

As a conference abstract, specific quantitative findings are not available in published form, though the work contributed to understanding neural…

Neuroimaging & New Technologies fMRI Neuroimaging Laboratory Study Theory & Mechanisms
[024]
Yuki Hamamoto, Takehiro Komatsu, Mariko Takeuchi, Hitoshi Yonemori, Seigo Ishimura, Yuko Sugisawa (2014)

Habituation processes of skin conductance response (SCR) and normalize pulse volume (NPV) in pseudo concealed information test

The study revealed differential habituation patterns between skin conductance and pulse volume measures in the CIT, suggesting that strategic timing…

Concealed Information Test (CIT) CIT Laboratory Study Japan International
[025]
Michael R. Winograd (2014)

The impact of prior knowledge from participant instructions in a mock crime P300 Concealed Information Test

Prior knowledge of a stolen item conveyed through experimental instructions caused 69% of innocent participants to be misclassified as guilty,…

Concealed Information Test (CIT) CIT EEG/P300 Laboratory Study Accuracy & Validity Theory & Mechanisms
[026]
Michelle C. Phillips (2013)

Deception and the misinformation effect: An event-related potential study

Deception produced strong parietal P3b suppression and a large frontal N400 negativity, while misinformation produced its own P3b suppression plus…

Neuroimaging & New Technologies EEG/P300 CIT Laboratory Study Theory & Mechanisms Accuracy & Validity
[027]
J. Peth, J. Kim, Matthias Gamer (2013)

Fixations and eye-blinks allow for detecting concealed crime related memories

Guilty participants displayed fewer but longer fixations on central crime details with reduced blink rates. Validity estimates were moderate (AUC…

Neuroimaging & New Technologies CIT Eye Tracking Laboratory Study Accuracy & Validity Theory & Mechanisms
[030]
L. Zvi, I. Nachson, Eitan Elaad (2012)

Effects of coping and cooperative instructions on guilty and informed innocents' physiological responses to concealed information

Guilty participants exhibited stronger physiological responses to critical items than informed innocents, and cooperative instructions reduced false positive rates by…

Concealed Information Test (CIT) CIT Laboratory Study Accuracy & Validity Theory & Mechanisms
[031]
M. A. Kireev S. Korotkov Medvedev (2012)

The possible role of an error detection mechanism in brain processing of deception

Both deceptive and honest manipulative actions activated overlapping brain networks including the bilateral prefrontal cortex, right anterior cingulate cortex, and…

Neuroimaging & New Technologies fMRI Neuroimaging Laboratory Study Theory & Mechanisms Accuracy & Validity
[033]
Xiaoqing Hu (2012)

Deception Awareness Improves P300-based Deception Detection in Concealed Information Tests

The deception-aware group achieved a 100% individual detection rate (10/10) compared to only 50% (5/10) in the control group, with…

Neuroimaging & New Technologies CIT EEG/P300 Laboratory Study Accuracy & Validity Theory & Mechanisms
[034]
I. Matsuda, T. Ogawa (2011)

Improved method for calculating the respiratory line length in the concealed information test

The weighted average method successfully removed systematic bias in respiration line length calculations and significantly increased discrimination performance compared to…

Scoring & Test Data Analysis CIT Laboratory Study Scoring Methods Accuracy & Validity
[035]
A. Sokolovsky, J. Rothenberg, Elena Labkovsky, J. Meixner, J. Peter Rosenfeld (2011)

A novel countermeasure against the reaction time index of countermeasure use in the P300-based complex trial protocol for detection of concealed information

Detection rates remained high (83-92%) based on P300 for all groups, but simultaneous countermeasure execution made reaction times indistinguishable from…

Countermeasures Research CIT EEG/P300 Laboratory Study Countermeasures Accuracy & Validity
[036]
Maxim Kireev (2010)

Brain mechanisms of deception

Regional cerebral blood flow assessment revealed anterior cingulate cortex involvement in deception, indicating that error detection mechanisms are fundamentally involved…

Neuroimaging & New Technologies fMRI Neuroimaging Laboratory Study Theory & Mechanisms Review Article
[037]
Wolfgang Ambach (2010)

Advances in the concealed information test: Introductory remarks

The editorial introduced research demonstrating that multimodal measurement combining autonomic responses with event-related potentials enhances CIT validity, and that various…

Concealed Information Test (CIT) CIT Review Article Theory & Mechanisms Accuracy & Validity Scoring Methods
[038]
Matthias Gamer (2010)

Does the guilty action test allow for differentiating guilty participants from informed innocents? A re-examination

Neither electrodermal, respiratory, nor heart rate responses differed by guilt status or questioning technique. Both GKT and GAT failed to…

Concealed Information Test (CIT) CIT Laboratory Study Accuracy & Validity Theory & Mechanisms
[040]
Izumi Matsuda, Hiroshi Nittono, Tokihiro Ogawa (2010)

Discrimination performance of event-related potentials in the autonomic-based Concealed Information Test

ERP measures detected participants missed by autonomic measures alone, and combining ERP with autonomic measures significantly improved discrimination performance. The…

Neuroimaging & New Technologies CIT EEG/P300 Laboratory Study Accuracy & Validity Computer Scoring
[042]
A. Osugi (2010)

Gap and connection between laboratory research and field application of the CIT in Japan

Laboratory and field CIT data showed convergent physiological patterns across all major autonomic measures (skin conductance increase, heart rate decrease,…

Concealed Information Test (CIT) CIT Field Study Japan International Theory & Mechanisms
[043]
J. Peter Rosenfeld, Xiaoqing Hu, Elena Labkovsky, J. Meixner, Michael R. Winograd (2009 • ERP REVIEW)

Review of Recent Studies and Issues Regarding the P300-Based Complex Trial Protocol for Detection of Concealed Information

Comprehensive review summarizing more than a dozen CTP studies. Documented diagnostic accuracy from 75–90%, described enhancements using N200, performance feedback,…

Meta-Analyses & Systematic Reviews CIT EEG/P300 Review Article Countermeasures Accuracy & Validity
[045]
J.P. M.R. Rosenfeld A. Winograd E.B. Haynes Labkovsky (2008)

Enhancing the complex trial protocol (CTP) and detecting concealed information in a mock crime scenario

The CTP achieved greater than 90% detection accuracy across all testing conditions including when participants attempted countermeasures. Countermeasure use was…

Concealed Information Test (CIT) CIT EEG/P300 Laboratory Study Countermeasures Counter-Countermeasures
[046]
Heinz Werner Gödert (2008)

Electrodermal and phasic heart rate responses in the Guilty Actions Test: Comparing guilty examinees to informed and uninformed innocents

Informed participants (both guilty and innocent-aware) showed equivalent SCR and heart rate deceleration patterns to crime-relevant items, indicating that the…

Laboratory & Analog Studies CIT Laboratory Study Accuracy & Validity Theory & Mechanisms Europe
[047]
B. J.P. Verschuere M. Rosenfeld E. Winograd J.R. Labkovsky Wiersema (2008)

The role of deception in the P300-based concealed information test

P300 memory detection was significant even without deceptive responding, demonstrating recognition is sufficient. However, deception improved detection accuracy, suggesting it…

Concealed Information Test (CIT) CIT EEG/P300 Laboratory Study Accuracy & Validity Theory & Mechanisms
[049]
Fren T. Y. Smulders (2008)

Combining P300 and SCR in the detection of concealed information

Both P300 and SCR independently discriminated crime-relevant from irrelevant stimuli in a mock crime CIT, but the two measures were…

Neuroimaging & New Technologies CIT EEG/P300 Laboratory Study Theory & Mechanisms
[050]
Fren T. Y. Smulders (2007)

The P300 is sensitive to concealed face recognition

P300-based CIT successfully detected concealed face recognition under high-familiarity and deceptive-intent conditions, but mere recognition alone without concealment motivation was…

Neuroimaging & New Technologies CIT EEG/P300 Neuroimaging Laboratory Study Accuracy & Validity
[051]
J. Peter Rosenfeld, J.R. Biroschak, John J. Furedy (2006)

P300-based detection of concealed autobiographical versus incidentally acquired information in target and non-target paradigms

Autobiographical probe items generated larger P300 amplitudes and higher detection rates than incidentally acquired information; removal of target stimuli did…

Neuroimaging & New Technologies CIT EEG/P300 Laboratory Study Accuracy & Validity
[052]
Eitan Elaad, Gershon Ben-Shakhar (2006)

Finger pulse waveform length in the detection of concealed information

FPWL achieved detection accuracy comparable to established measures (SCR .70–.84, RLL .73–.82), with improved performance when measures were combined. FPWL…

Concealed Information Test (CIT) CIT Laboratory Study Accuracy & Validity Scoring Methods Israel
[053]
Vahid Abootalebi, Mohammad Hassan Moradi, Mohammad Ali Khalilzadeh (2006 • P300 GKT COMPARISON)

A Comparison of Methods for ERP Assessment in a P300-Based GKT

Compared three classifiers for P300-based detection achieving 74–80% correct detection rates. Demonstrated potential of ERP methods though accuracy remained below…

Neuroimaging & New Technologies EEG/P300 CIT Laboratory Study Accuracy & Validity Machine Learning
[054]
Matthias Gamer, Hans-Georg Rill, Gerhard Vossel, Heinz Werner Gödert (2006)

Psychophysiological and vocal measures in the detection of guilty knowledge

The study provided one of the first rigorous laboratory tests comparing traditional psychophysiological measures against commercial VSA technology like TrusterPro.

Laboratory & Analog Studies CIT Laboratory Study Voice Stress Analysis Accuracy & Validity
[055]
F. Fang, Y. Liu, Z. Shen (2003)

Lie detection with contingent negative variation

CNV exhibited significantly more negative shifts for target faces (requiring deceptive responses) compared to non-target faces, with statistical significance across…

Neuroimaging & New Technologies EEG/P300 Neuroimaging Laboratory Study Theory & Mechanisms
[056]
Heinz Werner Gödert (2001)

Psychophysiological differentiation of deception: The effects of electrodermal lability and mode of responding on skin conductance and heart rate

The psychophysiological deception differentiation effect was robustly replicated under low emotional-stakes conditions, and was extended beyond skin conductance to phasic…

Psychophysiology & Autonomic Responses Laboratory Study Theory & Mechanisms Accuracy & Validity Europe
[057]
Matthew Soskins (2001)

The case for peak-to-peak measurement of P300 recorded at .3 hz high pass filter settings in detection of deception

The 0.3 Hz high-pass filter combined with peak-to-peak P300 amplitude measurement achieved 100% correct classification (26/26) in a laboratory deception…

Neuroimaging & New Technologies EEG/P300 CIT Laboratory Study Scoring Methods Accuracy & Validity
[058]
Matthew Soskins, J. Peter Rosenfeld, T. Niendam (2001)

The case for peak-to-peak measurement of P300 recorded at 0.3 Hz high pass filter settings in detection of deception

The combination of 0.3 Hz filter settings with peak-to-peak P300 measurement achieved 100% correct classification (26/26 participants) in a laboratory…

Neuroimaging & New Technologies EEG/P300 CIT Laboratory Study Accuracy & Validity Theory & Mechanisms
[059]
K. Fukuda (2001)

Eye blinks: new indices for the detection of deception

Blink rate patterns discriminated between relevant and irrelevant stimuli in a card-based guilty knowledge test, with more blinks occurring before…

Neuroimaging & New Technologies CIT Laboratory Study Eye Tracking Accuracy & Validity Theory & Mechanisms
[061]
John J. Furedy (1996)

Some elementary distinctions among, and comments concerning, the ‘control’ question ‘test’ (CQT) polygrapher's many problems: A reply to Honts, Kircher and Raskin

Furedy maintained that the CQT should be abandoned on logico-ethical, ethical, methodological, and evidential grounds, arguing that the technique's fundamental…

Foundational & Historical Research CQT Theory & Mechanisms Ethics & Policy Review Article
[062]
John J.B. Allen (1996)

Event-related potentials as indirect measures of recognition memory

ERP signals — particularly the centro-parietal P300 in the 500–1000 ms window — reliably distinguished recognized from unrecognized auditory stimuli…

Neuroimaging & New Technologies CIT EEG/P300 Laboratory Study Theory & Mechanisms Accuracy & Validity
[063]
John J. Furedy (1996)

The North American polygraph and psychophysiology: disinterested, uninterested, and interested perspectives

The North American research psychophysiological community has largely failed to meet standards of disinterestedness regarding psychophysiological detection of deception, representing…

Foundational & Historical Research CQT Theory & Mechanisms Ethics & Policy Review Article
[064]
Charles Robert Honts, John C. Kircher, David C. Raskin (1995)

Polygrapher's dilemma or psychologist's chimaera: a reply to Furedy's logico-ethical considerations for psychophysiological practitioners and researchers

The authors concluded that Furedy's concerns about the CQT were lacking on almost all counts and that his arguments were…

Foundational & Historical Research CQT Theory & Mechanisms Ethics & Policy Review Article
[065]
M.M. Johnson, J. Peter Rosenfeld (1992)

Oddball-evoked P300-based method of deception detection in the laboratory II: Utilization of non-selective activation of relevant knowledge

The study achieved 87% overall accuracy in classifying guilty (n=17) and innocent (n=14) subjects without pre-test selective rehearsal, demonstrating that…

Neuroimaging & New Technologies EEG/P300 Laboratory Study CIT Screening Accuracy & Validity
[066]
A. Vincent, John J. Furedy (1992)

Electrodermal differentiation of deception: potentially confounding and influencing factors

Voice latency and skin conductance both increased for difficult biographical questions, but only skin conductance showed the deceptive > honest…

Laboratory & Analog Studies Laboratory Study Theory & Mechanisms CQT
[067]
Leonard Saxe (1991)

Science and CQT polygraph tests: A theoretical critique

The CQT lacks construct validity because it assesses fear rather than deception, making proper validation impossible. While the test may…

Foundational & Historical Research CQT Theory & Mechanisms Review Article
[068]
John J. Furedy, R.T. Posner, A. Vincent (1991)

Electrodermal differentiation of deception: Perceived accuracy and perceived memorial content manipulations

Skin conductance responses to deceptive answers exceeded honest responses regardless of participants' beliefs about polygraph accuracy or the complexity of…

Psychophysiology & Autonomic Responses Laboratory Study Theory & Mechanisms Accuracy & Validity
[069]
Eitan Elaad, Gershon Ben-Shakhar (1991)

Effects of mental countermeasures on psychophysiological detection in the guilty knowledge test

Item-specific mental countermeasures tended to increase psychophysiological detection, whereas continuous dissociation strategies decreased detection efficiency, with patterns consistent across field…

Countermeasures Research CIT Countermeasures Laboratory Study Accuracy & Validity

Explore more research.

Search and filter our complete database of 3493 peer-reviewed studies from 1331 journals.

Need to book now? Our online booking system is open 24/7. Speak directly with our team about your test or booking.