Home › Polygraph Research › Journals › International Journal of Psychophysiology
Journal file
International Journal of Psychophysiology
69 peer-reviewed polygraph studies · 1991–2025
Authors in International Journal of Psychophysiology [122]
Research topics
All studies [69]
Every peer-reviewed study from International Journal of Psychophysiology in our database, ordered newest first.
Area measure of skin conductance in the Concealed Information Test
SC area showed acceptable performance for CIT classification and exceeded chance-level discrimination even for low-responsive participants, though equivalence with traditional…
Is the CIT susceptible to misleading information? A constructive replication
Misleading information reduced explicit memory of mock crime details, but physiological CIT responses (skin conductance and respiration) were only partially…
The effect of retroactive memory interference on the P300-based Complex Trial Protocol (CTP)
Retroactive memory interference did not threaten P300-based CTP accuracy, with significant probe vs. irrelevant amplitude differences maintained across all experimental…
What mechanisms underlie ERP-based concealed information detection?
P3 responses and multivariate brain patterns showed equivalent strength whether participants concealed or revealed information, but were strongly influenced by…
Increase of Lie Detection Accuracy through Integrated Measurement of Pupil Dilation and Polygraph
The integrated measurement of pupil dilation and polygraph increased lie detection accuracy compared to single-modality approaches, though specific accuracy rates…
The effect of countermeasures against the reaction time based concealed information test on the P300 index of knowledge recognition: A combined RT and P300-based test
Countermeasures successfully defeated the RT-based test by reversing the normal probe-irrelevant RT pattern, but paradoxically increased P300 probe-irrelevant differences, leading…
Contributions of personality dimensions to spontaneous and deliberate information processing in the guilty actions test
Introversion predicted enhanced skin conductance responses to critical items only during first presentations of early questions, while extraversion was linked…
The First Independent Study on the Complex Trial Protocol Version of the P300-Based Concealed Information Test
First independent replication of Rosenfeld’s Complex Trial Protocol. Corroborated accuracy and countermeasure resistance of the CTP when using probe vs.…
Superiority of visual (verbal) vs. auditory test presentation modality in a P300-based CIT: The complex-trial protocol for concealed autobiographical memory detection
Visual presentation produced significantly larger probe-irrelevant P300 differences (effect sizes 0.19-0.31) and higher detection accuracy than auditory presentation. The study…
Psychophysiological detection of deception and Preliminary Process Theory: a comment on Palmatier and Rovner (2015)
The commentary acknowledges common psychophysiological processes underlie CQT and CIT but finds arguments for Preliminary Process Theory unconvincing, calling for…
The cognitive mechanisms underlying deception: An event-related potential study
Lying produced significantly longer reaction times (d = 1.91), higher error rates (d = 1.24), an enhanced N200, and a…
The protection of innocent suspects: a comment on Palmatier and Rovner (2015)
The commentary argues that CQT and CIT differ fundamentally in how they protect innocent suspects, with this difference representing a…
Personality dimensions predict psychophysiological responses in the Concealed Information Test
Introversion predicted enhanced skin conductance responses to critical items only during the first repetition of early questions, explained by orienting…
The processes involved with fewer eyeblinks in a concealed information test
Fewer eyeblinks and longer first-blink latency occurred for crime-related items in both concealing and non-concealing groups, while heart rate differences…
Effects of countermeasures on P300-based concealed information test using a new multiple probe protocol
The study examined countermeasure resistance of a new multiple probe protocol for P300-based CIT, though specific detection rates and statistical…
Functional neuroimaging of deception
As a conference abstract, specific quantitative findings are not available in published form, though the work contributed to understanding neural…
Habituation processes of skin conductance response (SCR) and normalize pulse volume (NPV) in pseudo concealed information test
The study revealed differential habituation patterns between skin conductance and pulse volume measures in the CIT, suggesting that strategic timing…
The impact of prior knowledge from participant instructions in a mock crime P300 Concealed Information Test
Prior knowledge of a stolen item conveyed through experimental instructions caused 69% of innocent participants to be misclassified as guilty,…
Deception and the misinformation effect: An event-related potential study
Deception produced strong parietal P3b suppression and a large frontal N400 negativity, while misinformation produced its own P3b suppression plus…
Fixations and eye-blinks allow for detecting concealed crime related memories
Guilty participants displayed fewer but longer fixations on central crime details with reduced blink rates. Validity estimates were moderate (AUC…
Effects of coping and cooperative instructions on guilty and informed innocents' physiological responses to concealed information
Guilty participants exhibited stronger physiological responses to critical items than informed innocents, and cooperative instructions reduced false positive rates by…
The possible role of an error detection mechanism in brain processing of deception
Both deceptive and honest manipulative actions activated overlapping brain networks including the bilateral prefrontal cortex, right anterior cingulate cortex, and…
Deception Awareness Improves P300-based Deception Detection in Concealed Information Tests
The deception-aware group achieved a 100% individual detection rate (10/10) compared to only 50% (5/10) in the control group, with…
Improved method for calculating the respiratory line length in the concealed information test
The weighted average method successfully removed systematic bias in respiration line length calculations and significantly increased discrimination performance compared to…
A novel countermeasure against the reaction time index of countermeasure use in the P300-based complex trial protocol for detection of concealed information
Detection rates remained high (83-92%) based on P300 for all groups, but simultaneous countermeasure execution made reaction times indistinguishable from…
Brain mechanisms of deception
Regional cerebral blood flow assessment revealed anterior cingulate cortex involvement in deception, indicating that error detection mechanisms are fundamentally involved…
Advances in the concealed information test: Introductory remarks
The editorial introduced research demonstrating that multimodal measurement combining autonomic responses with event-related potentials enhances CIT validity, and that various…
Does the guilty action test allow for differentiating guilty participants from informed innocents? A re-examination
Neither electrodermal, respiratory, nor heart rate responses differed by guilt status or questioning technique. Both GKT and GAT failed to…
Discrimination performance of event-related potentials in the autonomic-based Concealed Information Test
ERP measures detected participants missed by autonomic measures alone, and combining ERP with autonomic measures significantly improved discrimination performance. The…
Gap and connection between laboratory research and field application of the CIT in Japan
Laboratory and field CIT data showed convergent physiological patterns across all major autonomic measures (skin conductance increase, heart rate decrease,…
Review of Recent Studies and Issues Regarding the P300-Based Complex Trial Protocol for Detection of Concealed Information
Comprehensive review summarizing more than a dozen CTP studies. Documented diagnostic accuracy from 75–90%, described enhancements using N200, performance feedback,…
Enhancing the complex trial protocol (CTP) and detecting concealed information in a mock crime scenario
The CTP achieved greater than 90% detection accuracy across all testing conditions including when participants attempted countermeasures. Countermeasure use was…
Electrodermal and phasic heart rate responses in the Guilty Actions Test: Comparing guilty examinees to informed and uninformed innocents
Informed participants (both guilty and innocent-aware) showed equivalent SCR and heart rate deceleration patterns to crime-relevant items, indicating that the…
The role of deception in the P300-based concealed information test
P300 memory detection was significant even without deceptive responding, demonstrating recognition is sufficient. However, deception improved detection accuracy, suggesting it…
Combining P300 and SCR in the detection of concealed information
Both P300 and SCR independently discriminated crime-relevant from irrelevant stimuli in a mock crime CIT, but the two measures were…
The P300 is sensitive to concealed face recognition
P300-based CIT successfully detected concealed face recognition under high-familiarity and deceptive-intent conditions, but mere recognition alone without concealment motivation was…
P300-based detection of concealed autobiographical versus incidentally acquired information in target and non-target paradigms
Autobiographical probe items generated larger P300 amplitudes and higher detection rates than incidentally acquired information; removal of target stimuli did…
Finger pulse waveform length in the detection of concealed information
FPWL achieved detection accuracy comparable to established measures (SCR .70–.84, RLL .73–.82), with improved performance when measures were combined. FPWL…
A Comparison of Methods for ERP Assessment in a P300-Based GKT
Compared three classifiers for P300-based detection achieving 74–80% correct detection rates. Demonstrated potential of ERP methods though accuracy remained below…
Psychophysiological and vocal measures in the detection of guilty knowledge
The study provided one of the first rigorous laboratory tests comparing traditional psychophysiological measures against commercial VSA technology like TrusterPro.
Lie detection with contingent negative variation
CNV exhibited significantly more negative shifts for target faces (requiring deceptive responses) compared to non-target faces, with statistical significance across…
Psychophysiological differentiation of deception: The effects of electrodermal lability and mode of responding on skin conductance and heart rate
The psychophysiological deception differentiation effect was robustly replicated under low emotional-stakes conditions, and was extended beyond skin conductance to phasic…
The case for peak-to-peak measurement of P300 recorded at .3 hz high pass filter settings in detection of deception
The 0.3 Hz high-pass filter combined with peak-to-peak P300 amplitude measurement achieved 100% correct classification (26/26) in a laboratory deception…
The case for peak-to-peak measurement of P300 recorded at 0.3 Hz high pass filter settings in detection of deception
The combination of 0.3 Hz filter settings with peak-to-peak P300 measurement achieved 100% correct classification (26/26 participants) in a laboratory…
Eye blinks: new indices for the detection of deception
Blink rate patterns discriminated between relevant and irrelevant stimuli in a card-based guilty knowledge test, with more blinks occurring before…
Some elementary distinctions among, and comments concerning, the ‘control’ question ‘test’ (CQT) polygrapher's many problems: A reply to Honts, Kircher and Raskin
Furedy maintained that the CQT should be abandoned on logico-ethical, ethical, methodological, and evidential grounds, arguing that the technique's fundamental…
Event-related potentials as indirect measures of recognition memory
ERP signals — particularly the centro-parietal P300 in the 500–1000 ms window — reliably distinguished recognized from unrecognized auditory stimuli…
The North American polygraph and psychophysiology: disinterested, uninterested, and interested perspectives
The North American research psychophysiological community has largely failed to meet standards of disinterestedness regarding psychophysiological detection of deception, representing…
Polygrapher's dilemma or psychologist's chimaera: a reply to Furedy's logico-ethical considerations for psychophysiological practitioners and researchers
The authors concluded that Furedy's concerns about the CQT were lacking on almost all counts and that his arguments were…
Oddball-evoked P300-based method of deception detection in the laboratory II: Utilization of non-selective activation of relevant knowledge
The study achieved 87% overall accuracy in classifying guilty (n=17) and innocent (n=14) subjects without pre-test selective rehearsal, demonstrating that…
Electrodermal differentiation of deception: potentially confounding and influencing factors
Voice latency and skin conductance both increased for difficult biographical questions, but only skin conductance showed the deceptive > honest…
Science and CQT polygraph tests: A theoretical critique
The CQT lacks construct validity because it assesses fear rather than deception, making proper validation impossible. While the test may…
Electrodermal differentiation of deception: Perceived accuracy and perceived memorial content manipulations
Skin conductance responses to deceptive answers exceeded honest responses regardless of participants' beliefs about polygraph accuracy or the complexity of…
Effects of mental countermeasures on psychophysiological detection in the guilty knowledge test
Item-specific mental countermeasures tended to increase psychophysiological detection, whereas continuous dissociation strategies decreased detection efficiency, with patterns consistent across field…
Explore more research.
Search and filter our complete database of 3493 peer-reviewed studies from 1331 journals.

