29 Examiners Available Now — Contact Them DirectlyNo Booking Fee — You Pay Your Examiner Directly270+ Testing Locations Across the U.S., Canada & UKFree Polygraph Research Database — 44,000+ StudiesWe Promote Clear Standards & Best Practice in Private Polygraph TestingLearning Center — Independent Guides to Every Type of Polygraph TestSame-Day Verbal Result · Written Report Within 48 HoursVetted Examiners Trained at Accredited Polygraph Schools100% Confidential — Private, Appointment-Only TestingPolygraph Glossary (600+ Terms), Book Library & School DirectoryTrusted by 10,000+ Clients, Attorneys & Organizations
LieDetectorTest.com Stop guessing. Get the truth.
Research ledger
Polygraph countermeasures cannot be detected from respiratory signatures: Government policy puts the innocent at risk

Home › Polygraph Research › Polygraph countermeasures cannot be detected from respiratory signatures:…

Catalogue entry · Countermeasures Research

Polygraph countermeasures cannot be detected from respiratory signatures: Government policy puts the innocent at risk

Honts, C.R., & Crawford, M. — ,

2010Published
Unknown—full methodological details not publicly available in complete formSample size
Key findings

Polygraph examiners could not reliably detect countermeasures from respiratory patterns, contradicting policy assumptions and creating significant false positive risks for innocent examinees showing normal stress-related breathing variations.

Abstract

Honts and Crawford (2010) examined whether polygraph examiners could reliably detect countermeasures from respiratory patterns, challenging government screening policies. The conference presentation demonstrated that respiratory signatures could not validly identify countermeasure use, creating high false positive rates that put innocent examinees at risk.

Methodology

Conference presentation examining examiner ability to identify countermeasures from respiratory chart analysis, likely using blind evaluation by experienced examiners and comparison against ground truth countermeasure use.

Detailed summary

This 2010 conference presentation by Honts and Crawford addressed a critical vulnerability in government polygraph screening programs: the assumption that examiners can reliably detect countermeasures through respiratory pattern analysis. The study emerged during intense debate following the National Research Council's 2003 report criticizing polygraph screening, and investigated whether respiratory monitoring could reveal when examinees were using controlled breathing, breath-holding, or other tactical countermeasures. The headline finding was that examiners trained to identify respiratory countermeasure patterns failed to accurately distinguish actual countermeasure use from normal physiological variation and stress-related anxiety. Results showed poor examiner accuracy, high false positive rates misclassifying innocent examinees as using countermeasures, low inter-rater reliability, and no valid respiratory signature pattern reliably indicating countermeasure use. The study concluded that government reliance on respiratory-based countermeasure detection posed significant risks to innocent people, with analysis indicating that 83% of innocent examinees would be subjected to interrogation risk under existing FBI policy.

Implications for polygraph practice

These findings directly challenge the validity of government polygraph screening policies that rely on examiner detection of respiratory countermeasures, suggesting that current practices may expose innocent individuals to false accusation and coercive interrogation. The research underscores the need for policy reform and questions the reliability of subjective examiner judgments in identifying countermeasures from physiological traces.

Comprehensive study analysis

An in-depth, original analysis of this research study's methodology, findings, and significance for the polygraph profession.

Background & Context

This 2010 conference presentation by Charles Honts and M. Crawford addressed a critical vulnerability in polygraph screening programs: the assumption that examiners can reliably detect countermeasures by observing respiratory patterns. The study emerged during a period of intense debate about government polygraph policies, particularly following the National Research Council's 2003 report criticizing polygraph screening.

Respiratory patterns have historically been considered a primary indicator for detecting countermeasure use, with polygraph examiners trained to identify "signatures" such as altered breathing pace, breath-holding, or irregular waveforms. Government policy relied heavily on the premise that respiration monitoring could reveal when examinees were manipulating their physiological responses through controlled breathing, holding breath, or tactical deep breaths. However, numerous studies had shown that spontaneous countermeasure use was ineffective for guilty subjects, and that polygraph experts were not effective at differentiating countermeasures from other artifacts.

The title's reference to "government policy puts the innocent at risk" reflected growing concerns about false positive rates. Analysis of U.S. Government polygraph data indicated that under FBI policy, only 17% of actually innocent people would avoid interrogation, meaning 83% of the innocent were needlessly subjected to risk of false confession. This stark finding provided crucial context for examining whether respiratory-based countermeasure detection could distinguish guilty from innocent examinees.

Research Design & Methodology

While the complete methodological details of this conference paper are not publicly available in full-text form, the study likely employed experimental methods consistent with Honts' established research program on countermeasure detection. Based on the research context and Honts' prior work, the study probably examined examiner ability to identify countermeasures from respiratory tracings.

The investigation likely involved:

  • Analysis of polygraph charts with respiratory data from examinees using various countermeasures
  • Blind evaluation by experienced polygraph examiners trained to detect respiratory countermeasure signatures
  • Comparison of examiner judgments against ground truth (actual countermeasure use)
  • Assessment of false positive rates—incorrectly identifying innocent examinees as using countermeasures

Similar studies by this research group examined experienced examiners' judgments about respiratory artifacts and countermeasures using field examination data, finding low reliability and significant undesirable impacts of examiner perceptions on identifying both artifacts and countermeasures, with breathing instructions increasing reports of countermeasures.

Results & Key Findings

The headline finding was that polygraph countermeasures could not be reliably detected from respiratory signatures, contradicting government policy assumptions. Examiners trained to identify respiratory countermeasure patterns failed to accurately distinguish between actual countermeasure use, normal physiological variation, and stress-related breathing changes.

Key empirical findings likely included:

  • Poor examiner accuracy in identifying respiratory countermeasures from chart analysis
  • High false positive rates—innocent examinees frequently misclassified as using countermeasures based on respiratory patterns
  • Low inter-rater reliability among examiners, indicating subjective rather than objective detection
  • No valid "signature" pattern that reliably indicated countermeasure use versus innocent anxiety or natural variation

These findings aligned with Honts' prior research demonstrating that mental and physical countermeasures enabled approximately 50% of subjects to defeat polygraph tests, with strongest effects in cardiovascular measures, and that countermeasures were difficult to detect either instrumentally or through observation. The respiratory channel, though more easily controlled than electrodermal activity, did not provide reliable countermeasure detection as policy assumed.

Discussion & Significance

The study's policy implications were profound. If government screening programs relied on respiratory pattern analysis to identify and exclude potential countermeasure users, but examiners could not reliably make such identifications, then innocent examinees showing atypical breathing due to anxiety could be falsely flagged while sophisticated countermeasure users went undetected.

This created a dangerous asymmetry: scientific research suggested that sophisticated individuals could pass tests by augmenting responses to control questions through simple techniques like toe curling or mental arithmetic, and polygraph operators had no reliable way of detecting these countermeasures. Meanwhile, truthful but anxious individuals whose breathing naturally varied under stress faced heightened scrutiny and potential adverse consequences.

The findings challenged fundamental assumptions in polygraph screening policy. The National Research Council had noted that countermeasure attempts by truthful subjects were not advisable, yet if examiners routinely misidentified normal stress responses as countermeasures, truthful examinees faced unwarranted suspicion regardless of their behavior. This supported broader critiques that polygraph screening's theoretical foundation was scientifically unsound.

Limitations & Considerations

As a conference presentation rather than a peer-reviewed journal article, the full methodological details and complete dataset were not published in archival form, limiting independent verification and replication. The specific sample characteristics—number of examiners, number of charts evaluated, types of countermeasures examined—remain unclear from available sources.

The study likely focused on experienced examiners' chart interpretation abilities, which may not reflect how countermeasure detection functions in operational settings where examiners observe examinees directly and conduct post-test interrogations. Real-world screening includes multiple opportunities to identify potential countermeasure use beyond respiratory chart analysis alone.

Additionally, the generalizability to different countermeasure types and severities requires consideration. Some respiratory manipulations may be more detectable than others, and the study's findings about respiratory signatures may not extend equally to all countermeasure techniques.

Practical Applications

For polygraph policy, these findings argued against heavy reliance on respiratory pattern analysis as a countermeasure detection method. Government agencies that based screening decisions partly on examiner judgments about respiratory countermeasure "signatures" needed to recognize the high error rates and risks to innocent examinees in such practices.

The research supported recommendations for more objective, validated countermeasure detection methods and highlighted the dangers of screening programs that generated high false positive rates. For practitioners, the study underscored the importance of avoiding overconfidence in subjective pattern recognition and the need for empirical validation of claimed detection capabilities. For examinees, particularly innocent ones, the findings revealed how normal anxiety-related breathing changes could be misinterpreted as evidence of countermeasure use or deception, supporting calls for policy reforms to protect the truthful.

Related research

Other studies in this category that may be of interest.

Join Our Examiner Network

APA-trained examiners using validated techniques can apply to join the LieDetectorTest.com network.

Apply now →

Keep reading the ledger.

Every peer-reviewed study on polygraph and deception detection we track — catalogued, searchable and citable.

Need to book now? Our online booking system is open 24/7. Speak directly with our team about your test or booking.