29 Examiners Available Now — Contact Them DirectlyNo Booking Fee — You Pay Your Examiner Directly270+ Testing Locations Across the U.S., Canada & UKFree Polygraph Research Database — 44,000+ StudiesWe Promote Clear Standards & Best Practice in Private Polygraph TestingLearning Center — Independent Guides to Every Type of Polygraph TestSame-Day Verbal Result · Written Report Within 48 HoursVetted Examiners Trained at Accredited Polygraph Schools100% Confidential — Private, Appointment-Only TestingPolygraph Glossary (600+ Terms), Book Library & School DirectoryTrusted by 10,000+ Clients, Attorneys & Organizations
LieDetectorTest.com Stop guessing. Get the truth.
Research ledger
Physiological detection of deception: Measurement of responses to questions and answers during countermeasure maneuvers

Home › Polygraph Research › Physiological detection of deception: Measurement of responses to…

Catalogue entry · Countermeasures Research

Physiological detection of deception: Measurement of responses to questions and answers during countermeasure maneuvers

Dawson, M.E. — Psychophysiology,

1981Published
Key findings

Professional actors' mental countermeasures proved completely ineffective, with 100% of guilty subjects correctly detected and no false negatives. However, innocent subjects experienced false positive rates of 17-25%, and physiological responses to questions were more valid indicators of deception than responses to verbal answers.

Abstract

This 1980 laboratory study examined whether professional actors trained in the Stanislavsky method could use mental countermeasures to defeat polygraph testing. Twenty-four actors participated in a mock-crime scenario, with half guilty and half innocent, tested using control question techniques including a novel delayed answer procedure. Despite their professional training in emotional control, guilty actors achieved 100% detection rates while innocent subjects showed 17-25% false positive rates depending on the physiological measure used.

Methodology

Laboratory mock-crime study with 24 professional actors (12 guilty, 12 innocent) tested using control question technique with both immediate and delayed (8-second) answer formats. Skin resistance, cardiovascular, and respiratory measures were recorded and evaluated both quantitatively and by an independent field examiner.

Comprehensive study analysis

An in-depth, original analysis of this research study's methodology, findings, and significance for the polygraph profession.

Background & Context

The attempt by guilty subjects to appear innocent represented a critical concern in polygraph testing during the late 1970s. This 1980 study emerged during an important period of polygraph research when scientists were debating the fundamental validity of physiological deception detection and exploring how test procedures could be manipulated or defeated. The research addressed a critical vulnerability: whether trained actors—professionals skilled in emotional control and deception—could successfully employ mental countermeasures to appear innocent.

A distinctive innovation in this research was the use of a delayed answer technique (DAT) that allowed separate measurement of physiological responses to questions versus answers by having subjects delay their verbal answer for 8 seconds. This methodological approach enabled researchers to examine a fundamental question about polygraph testing: whether the act of deception itself (during question processing) or the verbal lie (the answer) generated stronger physiological markers.

The study also confronted the "actor problem"—whether individuals with professional training in emotional simulation could defeat physiological detection. Student actors trained in the Stanislavsky method of acting provided an especially rigorous test population, as this method emphasizes authentic emotional experience rather than mere surface performance.

Research Design & Methodology

Twenty-four student actors aged 19 to 52 years trained in the Stanislavsky method participated, with 12 assigned to a guilty group (6 males, 6 females) and 12 to an innocent group (7 males, 5 females). The mock-crime scenario created realistic motivation, as all subjects were motivated to appear innocent to obtain a monetary bonus and exhibit their acting ability.

The experimental design employed a control question detection test in two versions: one with immediate verbal answers (IAT) and one requiring subjects to delay their verbal answer for 8 seconds (DAT). Key methodological features included:

  • Skin resistance responses, cardiovascular changes, and respiration were recorded
  • Both traditional immediate answering and the novel delayed answer technique
  • Professional acting training in all participants, essentially teaching them mental countermeasures
  • Independent chart evaluation by a field examiner in addition to quantitative scoring

The delayed answer technique was particularly innovative, creating an 8-second window between question presentation and verbal response to isolate physiological reactions to question content from reactions associated with producing the verbal lie.

Results & Key Findings

Attempts by guilty subjects to appear innocent were totally ineffective, with 0% errors for guilty subjects using each physiological measure. However, the findings revealed an important asymmetry in detection accuracy. The headline result demonstrated 100% accuracy in detecting guilty subjects but considerably lower performance with innocent subjects.

Specific accuracy findings included:

  • Decisions were 100 percent correct with guilty subjects
  • A total of 17 percent of subjects classified as 'deceptive' were truly innocent
  • Errors occurred more frequently with innocent subjects (between 17% and 25% depending on the measure used) than with guilty subjects (0% with each measure)
  • Physiological changes occurring in response to questions were more valid indicators of deception and nondeception than those occurring in response to the verbal answer

Skin resistance responses proved to be the most useful and consistent measure on an individual basis, while cardiovascular measures were useful but less consistent, and respiratory measures (cycle time and amplitude) were unreliable. Critically, reactions were observed shortly after the question started and prior to the subject's answer, indicating that attempted deception could be detected even if the subject remained silent.

Discussion & Significance

The findings challenged assumptions about countermeasure effectiveness by demonstrating that even professionally trained actors could not successfully defeat the control question test through mental countermeasures alone. Despite examining whether training in mental countermeasure could be used by guilty subjects to successfully appear non-deceptive, results strongly indicated this type of countermeasure was ineffective because no false-negative decisions were obtained. This contrasted sharply with later research by Honts and colleagues in the mid-1980s showing physical and mental countermeasures could defeat polygraph tests approximately 50% of the time.

The findings suggested the control question technique may be more useful in 'clearing' truly innocent subjects than in conclusively identifying truly guilty subjects—an observation with significant implications for polygraph use in criminal investigations where protecting the innocent is paramount. The superior validity of responses to questions versus answers supported cognitive models emphasizing that recognition and cognitive processing of personally relevant information drive physiological reactivity more than the motor act of lying.

The study provided important evidence for the temporal dynamics of deception detection. By separating question-evoked from answer-evoked responses, Dawson demonstrated that the critical physiological reactions occurred during information processing rather than during response execution, lending support to theoretical models emphasizing cognitive appraisal and recognition processes in deception detection.

Limitations & Considerations

Several methodological constraints limited generalizability to field settings. Variables affecting generalizability of results to field situations were discussed, including the mock-crime paradigm's inherently lower stakes compared to actual criminal investigations. The monetary incentive and opportunity to demonstrate acting ability, while motivating, cannot fully replicate the consequences of real criminal prosecution.

The finding that innocent subjects showed higher error rates (17-25%) raised concerns about false positive outcomes in applied settings. Honts later raised the possibility that the null countermeasure effect observed by Dawson was due to subjects not being informed about the nature of the CQT and consequently being unable to apply their mental countermeasures strategically. Without understanding control question methodology, even trained actors may not have known which questions required physiological augmentation.

The small sample size (N=24) and use of a specialized population (professional actors) limited statistical power and population generalizability. The delayed answer technique, while scientifically valuable, represented an artificial testing condition rarely if ever used in field polygraph examinations, potentially limiting practical applicability of those specific findings.

Practical Applications

This research provided reassurance to polygraph practitioners that mental countermeasures based on acting training or emotional control alone may be insufficient to defeat properly administered control question tests. The finding that physiological changes to questions were more valid indicators than those to answers supported the practice of carefully observing reactions during question presentation rather than focusing exclusively on the answer period.

The identification of skin resistance responses as the most useful and consistent measure on an individual basis reinforced the primacy of electrodermal activity in operational polygraph testing. For consumers and examinees, the research demonstrated that attempts to mentally control responses through theatrical training provided no protection against detection when guilty. However, the elevated false positive rate among innocent subjects underscored the importance of proper chart interpretation and the value of corroborating evidence beyond polygraph results alone in investigative contexts.

Read the original study

The analysis above is original editorial content based on our review of this research. For the complete study including full data, methodology details, and author discussion, access the original publication below.

Related research

Other studies in this category that may be of interest.

Join Our Examiner Network

APA-trained examiners using validated techniques can apply to join the LieDetectorTest.com network.

Apply now →

Keep reading the ledger.

Every peer-reviewed study on polygraph and deception detection we track — catalogued, searchable and citable.

Need to book now? Our online booking system is open 24/7. Speak directly with our team about your test or booking.