constant current method

Definition
The constant current method is a technique for measuring skin resistance in which the electrical current applied to the skin is held constant while changes in resistance are recorded. It is one of two exosomatic approaches to electrodermal measurement, the other being the constant voltage method.

What Is the Constant Current Method?

The constant current method is an exosomatic technique for measuring electrodermal activity in which a constant, small electrical current is applied to the skin and the resulting voltage is measured. Because the current remains fixed, changes in voltage directly reflect changes in skin resistance (by Ohm's law: V = I × R). As eccrine sweat gland activity increases, skin resistance decreases, producing a measurable voltage change.

Comparison with Constant Voltage Method

The constant current method is the counterpart to the constant voltage method, which applies a constant voltage and measures changes in current flow (reflecting skin conductance). Both methods measure the same underlying phenomenon — changes in the electrical properties of the skin caused by sweat gland activity — but they express the measurement in different units (resistance in ohms versus conductance in siemens). Modern polygraph instruments typically use the constant voltage method to measure skin conductance, as conductance has a more linear relationship with sweat gland activity than resistance.

Technical Implementation

The constant current method uses electrodes placed on the fingers or palmar surface through which a very small current (typically microamperes) passes. The current level must be low enough to avoid skin polarisation effects or discomfort while being sufficient to produce measurable voltage changes. A Wheatstone bridge circuit is often used to detect and amplify the small voltage changes that occur with changes in skin resistance.

Historical Context

Both constant current and constant voltage methods have been used throughout the history of electrodermal measurement in polygraph testing. The choice between them was historically influenced by available electronics technology and instrument design. Modern digital polygraph systems predominantly use the constant voltage (conductance) method, which has become the standard in psychophysiological research and polygraph practice.

Cross-references

More scoring terms in this glossary
Hit Rate The overall percentage of correct classifications (both true positives and true negatives) produced by a polygraph te... 7-position scale The 7-position scale is the most widely used system for assigning numerical values to physiological responses in PDD ... Logistic Regression A statistical classification method used in polygraph scoring algorithms (including OSS-3) that estimates the probabi... Defensible Dozen A mnemonic term for the approximately twelve validated physiological features used in polygraph chart interpretation.... Overfitting A statistical problem where a scoring algorithm performs very well on training data but poorly on new data. Occurs wh... chi-square test The chi-square test (χ²) is a non-parametric inferential statistical test used to evaluate relationships between cate...

Need a lie detector test?

Book with an examiner trained to APA standards at one of our 140+ locations nationwide.

Need to book now? Our online booking system is open 24/7. Speak directly with our team about your test or booking.