analysis spot
What Is an Analysis Spot?
An analysis spot (also called a scoring spot or comparison spot) is a specific location on a polygraph chart where the examiner compares physiological responses to a relevant question against responses to an adjacent comparison question. Each analysis spot represents one point of within-chart comparison and generates a spot score for each physiological channel being evaluated.
How Analysis Spots Work
In Comparison Question Technique formats, questions are arranged in a structured sequence that places each relevant question near one or more comparison questions. An analysis spot pairs a specific relevant question with the comparison question designated to serve as its control. The examiner (or scoring algorithm) evaluates the physiological responses at both question locations and assigns a numerical score reflecting the relative strength of responding.
In the 7-position scale, each analysis spot receives a score from -3 to +3 for each channel (electrodermal, respiratory, and cardiovascular). Negative scores indicate the relevant question produced a stronger response; positive scores indicate the comparison question was stronger.
Spot Pairing Rules
Different validated techniques use different rules for pairing relevant and comparison questions at each analysis spot. The Backster Zone Comparison Technique uses the Either-Or Rule, which allows the examiner to select whichever of two neighbouring comparison questions produced the stronger response. The Utah approach uses a fixed pairing where each relevant question is always compared to the same designated comparison question. These pairing rules are part of what defines each technique and must be followed precisely for results to be considered valid.
Aggregation into Total Scores
The individual spot scores from all analysis spots across all charts are combined to produce a subtotal score for each channel and ultimately a grand total that determines the examination outcome. The total is compared against validated cut-scores to reach a diagnostic opinion of DI, NDI, or INC.
Quality Considerations
For an analysis spot to yield valid data, the physiological tracings at both the relevant and comparison question locations must be free of artefacts, distortion, and movement interference. If either response location is compromised, the spot score may need to be marked as unscorable or assigned a zero. The quality control review process evaluates whether all analysis spots meet the minimum standards for reliable scoring.
Cross-references
More scoring terms in this glossaryNeed a lie detector test?
Book with an examiner trained to APA standards at one of our 140+ locations nationwide.